LADYCLIX.NL ≡ Carrosserie Gereedschap Haspels Home & Garden Laptop Bags
  • Fluke Industrial

  • Fluke 116 Digital HVAC Multimeter

Fluke 116 Digital HVAC Multimeter

$63.73 $79.03
Product Specification Specifications Maximum voltage between any terminal and earth ground 600 V Safety IEC 61010-1: Pollution Degree 2IEC 61010-2-033: CAT III 600V Display Digital: 6,000 counts, updates 4 per second Bar graph 33 segments, updates 32 per second Operating temperature -10°C to 50°C Storage temperature -40°C to 60°C Battery type 9 volt Alkaline, IEC 6LR61 Battery life 400 hours typical, without backlight Accuracy Specifications DC millivolts Range/resolution 600.0 mV / 0.1 mV Accuracy ±([% of reading] [counts]): 0.5% 2 DC volts Range/resolution 6.000 V / 0.001 V60.00 V / 0.01 V600.00 V / 0.1 V Accuracy ±([% of reading] [counts]): 0.5% 2 Auto volts Range/resolution 600.0 V / 0.1 V Accuracy 2.0% 3 (DC, 45 Hz to 500 Hz)4.0% 3 (500 Hz to 1 kHz) AC millivolts1 True RMS Range/resolution 600.0 mV / 0.1 mV Accuracy 1.0% 3 (DC, 45 Hz to 500 Hz)2.0% 3 (500 Hz to 1 kHz) AC volts1 True RMS Range/resolution 6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 V Accuracy 1.0% 3 (DC, 45 Hz to 500 Hz)2.0% 3 (500 Hz to 1 kHz) Continuity Range/resolution 600 Ω / 1 Ω Accuracy Beeper on 250 Ω detects opens or shorts of500 μs or longer. Ohms Range/resolution 600.0 Ω / 0.1 Ω6.000 kΩ / 0.001 kΩ60.00 kΩ / 0.01 kΩ600.0 kΩ / 0.1 kΩ6.000 MΩ / 0.001 MΩ Accuracy 0.9% 1 Range/Resolution 40.00 MΩ / 0.01 MΩ Accuracy 5% 2 Diode Test Range/resolution 2.00 V / 0.001 V Accuracy 0.9% 2 Capacitance Range/resolution 1000 nF / 1 nF10.00 μF / 0.01 μF100.0 μF / 0.1 μF9999 μF / 1 μF100 μF to 1000 μF Accuracy 1.9% 2 Range/resolution 1000 μF Accuracy 5% 20% Lo-Z Capacitance Range 1 nF to 500 μF Accuracy 10% 2 typical Temperature²(Type-K thermocouple) Range/resolution -40°C to 400°C / 0.1°C Accuracy 1% 10² Range/resolution -40°F to 752°F / 0.2°F Accuracy 1% 18² AC μA true-rms (45 Hz to 500 Hz) Range/resolution 600.0 μA / 0.1 μA Accuracy 1.5% 3 DC μamps Range/resolution 600.0 μA / 0.1 μA Accuracy 1.0% 2 Hz (V or A input)² Range/resolution 99.99 Hz / 0.01 Hz999.9 Hz / 0.1 Hz9.999 kHz / 0.001 Hz50.00 kHz / 0.01 Hz Accuracy 0.1% 2 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. Mechanical and General Specifications Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) Weight 550 g Warranty 3 years
Fluke Industrial

Fluke Industrial

  • Fluke 116 Digital HVAC Multimeter
    $63.73 $79.03

© 2026 - LADYCLIX.NL